ZN3750CDN-M2/M3 coupling and decoupling network

coupling and decoupling networ

Coupling and decoupling devices are used to properly couple disturbance signals to various cables connected to the equipment under test; and to prevent test signals from affecting non-device equipment and systems under test

0

0

0

发布时间: 2023-01-05 16:32:41

ZN3750CDN-M2/M3 coupling and decoupling network

About:

The CDN-M2/M3 coupling and decoupling network is designed according to the requirements of the National Standard of the People's Republic of China GB/T17626.6-2008/IEC61000-4-6:2006 for the CDN-M2/M3 coupling and decoupling network (CDN -M2 double line, CDN-M3 three line). This instrument combines CDN-M2 and CDN-M3 into one; according to the different needs of the user, the user can conveniently select through the buttons on the upper panel of the instrument.

Coupling and decoupling devices are used to properly couple disturbance signals to various cables connected to the equipment under test; and to prevent test signals from affecting non-device equipment and systems under test; according to GB/T17626.6-2008/IEC61000-4 -6: 2006; CDN coupling and decoupling networks are used to measure the performance of the conducted disturbance immunity of the equipment under test in the range of 9k ~ 80MHz.

Coupling and decoupling devices (i.e. CDN) can be used for 30M~300MHz radiation disturbance measurement of electrical lighting equipment; according to the national standard of the People's Republic of China GB17743-2007/CISPR15:2005; for specific measurement methods, please refer to the above standards (will be introduced in detail in the application ).

Environmental usage conditions of this instrument: working temperature 0℃~40℃.

Characteristics:

1. Frequency range 150kHz~230MHz

2. Port impedance|Zce|=150Ω

150kHz~26MHz 150Ω±20Ω

26MHz~80MHz 150Ω+60Ω-45Ω

80MHz~230MHz 150Ω±60Ω

3. Voltage division coefficient (EUT end and RF end)

150kHz~230M 9.5dB +3dB/-1dB

4. Decoupling coefficient (AE end and RF end)

150 kHz: >20dB

1.5 MHz: >60dB

30MHz: > 50dB

230MHz: >25dB

5. Power supply (EUT end and AE end)

(1) Voltage range: AC 0~250V

DC 0~400V

(2)Current range: 0~16A

(3) Frequency range: 0~60Hz

6. Signal port: BNC 50Ω (maximum input signal 2W)

7. Overall dimensions: 200×120×100 (mm)

8. Instrument weight: 1.3kg