coupling and decoupling networ
ZN3750-A coupling/decoupling network CDN-M1, the production design of this product complies with the national standard of the People's Republic of China GB/T17626.6-2008/IEC61000-4-6:2006
0
0
0
发布时间: 2023-01-05 16:50:15
ZN3750-A coupling/decoupling network CDN-M1, the production design of this product complies with the national standard GB/T17626.6-2008/IEC61000-4-6:2006 of the People's Republic of China,
Coupling and decoupling devices are used to properly couple disturbance signals to various cables connected to the equipment under test; and to prevent test signals from affecting non-device equipment and systems under test; according to GB/T17626.6-2008/IEC61000-4 -6: 2006; CDN-M1 coupling and decoupling network is used to measure the performance of the conducted disturbance immunity of the equipment under test within the range of 9k ~ 80MHz.
Coupling and decoupling devices (i.e. CDN) can be used for 30M~300MHz radiation disturbance measurement of electrical lighting equipment; according to the national standard of the People's Republic of China GB17743-2007/CISPR15:2005; for specific measurement methods, please refer to the above standards.
Environmental usage conditions of this instrument: working temperature 0℃~40℃.
1. Frequency range 150kHz~230MHz
2. Port impedance|Zce|=150Ω
150kHz~26MHz 150Ω±20Ω
26MHz~80MHz 150Ω+60Ω-45Ω
80MHz~230MHz 150Ω±60Ω
3. Voltage division coefficient (EUT end and RF end)
150kHz~230M 9.5dB +3dB/-1dB
4. Decoupling coefficient (AE end and RF end)
150 kHz: >20dB
1.5 MHz: >60dB
30 MHz: >45dB
230MHz: >25dB
5. Power supply (EUT end and AE end)
(1) Voltage range: AC 0~250V
DC 0~400V
(2)Current range: 0~16A
(3) Frequency range: 0~60Hz
6. Signal port: BNC 50Ω (maximum input signal 2W)
7. Dimensions: 200×120×105 (mm)
8. Instrument weight: 1.8kg