ZN23201 Absorptive Power Clamp

EMC Test Clamp

ZN23201 Absorptive Power Clamp is mainly composed of a high-frequency transformer and an absorber. The absorber is used as a load resistor. The transformer is mainly used to measure the high-frequency interference power on the wire in the frequency range of 30MHz to 1000MHz. Comply with the relevant clauses in CISPR16-1-3:2004 and national standard 6113.103-2008.

0

0

0

发布时间: 2023-01-05 16:55:29

ZN23201 Absorptive Power Clamp

About:

Absorptive power clamp is one of the supporting equipment for electromagnetic interference power measurement. It is suitable for measuring the electromagnetic power passing through the power line of household appliances, electric tools, etc., or measuring the interference suppression effect of the ignition system and the electromagnetic sensitivity of the receiving equipment. In addition, it can also be used to measure the shielding effect of radio frequency cables.

ZN23201 Absorptive Power Clamp is mainly composed of a high-frequency transformer and an absorber. The absorber is used as a load resistor. The transformer is mainly used to measure the high-frequency interference power on the wire in the frequency range of 30MHz to 1000MHz. Comply with the relevant clauses in CISPR16-1-3:2004 and national standard 6113.103-2008.

Characteristics:

1.1 Temperature:
a. Rated operating range: 0~40℃
b. Storage range: 40~60℃
1.2 Humidity:
a. Rated operating range: 40°C (20-90)%RH
b. Storage range: 50℃ 90%RH
1.3 Atmospheric pressure (860~1060) mbar
1.4 Mechanical environment
The anti-vibration, shock and transportation performance of this equipment should meet the requirements of Group II in SJ2075-82 Environmental Test for Electronic Measuring Instruments, General Program.
2. Working characteristics
2.1 Frequency range: 30MHz~1000MHz
2.2 Output impedance: 50Ω
2.3 The insertion loss of the absorption clamp is 13dB~22dB, 
2.4 The decoupling DF of the absorbing clamp is greater than 21dB,
2.5 The absorbing clamp decoupling factor DR is greater than 30dB,
2.6 The diameter of the cable under test is allowed: less than 20mm
2.8 Dimensions and weight
a. Dimensions: 641×110×98mm
b. Weight about: 5.5kg

The absorption power clamp is composed of a clamp-shaped ferrite absorber and a clamp-shaped high-frequency current transformer, which surrounds an insulated wire to measure the interference power on the wire. After the interference current flowing through the wire is converted into a voltage, it is indicated by the radio interference measuring instrument. When a ferrite snubber surrounds a coaxial cable, its job is to attenuate unwanted currents on the cable shield.